Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
parts:0055421017 [2025/08/06 07:30] – created john5788parts:0055421017 [2025/10/14 06:54] (current) – [Data] john5788
Line 1: Line 1:
 ====== Temperature Sensor (005 542 10 17) ====== ====== Temperature Sensor (005 542 10 17) ======
 +<grid>
 +<col sm="6">
 +<panel type="default" title="Temperature Sensor" subtitle="Coolant temperature sensor used for instrument cluster gauge">
 +<panel-body>
 +<image shape="responsive">{{ parts:0055421017.jpg }}</image>
 +
 +^ Field        ^ Value                  ^
 +| Part number(s)  | 005 542 10 17, 005 542 26 17           |
 +| Used on      | M100, M102, M103, M104, M110, M111, M117, M119, M120, M601, M602, M603 |
 +| Status       | Available as of July 2026       |
 +
 +</panel-body>
 +</panel>
 +</col>
 +</grid>
 +
 +===== Data =====
 +
 +<panel type="default" title="Steinhart–Hart Equation">
 +<panel-body>
 +**Equation:**  
 +<code>
 +1/T = A + B·ln(R) + C·[ln(R)]³
 +</code>
 +
 +**Coefficients:**  
 +  * A = 0.001763  
 +  * B = 0.0002380  
 +  * C = 1.83×10⁻⁷  
 +
 +**Where:**  
 +  * T = temperature in Kelvin  
 +  * R = resistance in ohms  
 +  * To convert to °C: **T(°C) = T(K) − 273.15**
 +</panel-body>
 +</panel>
 +
 +<grid>
 +<col sm="6">
 +<panel type="default" title="Measured Test Values">
 +<panel-body>
 +^ **Temperature (°C)** ^ **Resistance (Ω)** ^
 +| 100.0 | 43.5 |
 +| 79.3  | 95.1 |
 +| 59.8  | 155.2 |
 +| 44.7  | 287.9 |
 +| 1.55  | 1922 |
 +</panel-body>
 +</panel>
 +</col>
 +
 +<col sm="6">
 +<panel type="default" title="Resistance vs Temperature Curve">
 +<panel-body>
 +<image shape="responsive">{{ parts:0055421017_curve_chart.png }}</image>
 +</panel-body>
 +</panel>
 +</col>
 +</grid>
 +
 +
  • parts/0055421017.1754465439.txt.gz
  • Last modified: 2025/08/06 07:30
  • by john5788