This is an old revision of the document!


Overvoltage Protection Relay

A 5, 7, or 9-pin overvoltage protection relay is installed depending on the vehicle model and special equipment. This relay protects the control units (ABS, CIS-E, etc.) from excessively high voltage.

The battery voltage is present continuously at relay terminal 30. With the 7 and 9-pin versions the battery voltage is also connected to terminal 30a over the 10 A flat plug-in fuse. When the ignition/starter switch is turned to position 2 (driving position), the voltage is present at terminal 15 causing the relay to pull in. Power is supplied to terminals 87 (5-pin version) or 87E and 87L (7 and 9-pin versions).

Voltages > 22 V in the vehicle electrical system are connected directly to ground by the Z diode (fuse defective).

In the event of overloads occurring after the overvoltage cutout, the circuit is interrupted by the 10 A flat plug-in fuse. The 9-pin version is also fused separately at terminals 87E and 87L, whereby when the fuse for 87E blows 87L is also switched off.

Pinout

Brand Part number
WIX 51145
K&N PS7008
MicroGard MGL51145
ACDelco PF2146
Bosch 72194WS
Mann HU7271X
OVP pinout
5-pin OVP
7-pin OVP
9-pin OVP